- Po stronie serwera Syngo.via nie widzę błędów poza odpowiedzią z serwera PACS.
- Message: The remote node with AET NRSTORE has interrupted the Dicom Query with DIMSE status "Failure: Identifier does not match SOP class" (Code: 0xA900).
- ID: syngo.Services.TF.Common.Messages.DicomFindScuDimseError
- Severity: Error
- Timestamp: 2023-06-08T15:47:12.195-07:00
- Process Name: C:Program FilesSiemenssyngobinsyngo.Services.sDM.Server.exe
- Process Id: 48444
- Thread Name: syngo WB 86 AOM standard processor [SRV]
- Thread Id: 52196
- AppDomain: syngo.Services.sDM.Server.exe
- Machine: SYNGOVIA
- EventSource: syngo_TransferFramework
- Process Start Time: 2023-06-08T05:00:23.778-07:00
- Extended Properties: MsgCreateTime - 2023-06-08T15:47:12.195-07:00
- BuildNumber - VIA.PCP.VB60A.HF03.NB_20220519.1
- syngoSource - syngo.Services.sDM.NavigatorService.CdmaDataFetcher
- ExceptionId - 0_341289192E2E8C04266E9DA14BB109EEE87311F641396D0AF904B554A62B16
- ExceptionInstanceId - 409939e7-7b60-4cfa-8d9d-6e84ddaab0b1
- OriginalSeverity – Error
- Message: An exception of type 'syngo.Services.TF.ProcessControl.Activities.Network.Dicom.DicomServiceNetworkException' occurred and was caught.
- --------------------------------------------------------------------------------------------------------------------------------------
- 2023-06-08T15:47:12.195-07:00
- Exception Messages:
- DicomServiceNetworkException: failure dimse code received for CFIND, dimse status: 0xA900 (CFindFailureInvalidDataset), Failure: Identifier does not match SOP class, Error Comment: Invalid query
- QueryExecutionException: Protocol aborted
- NavigatorCDMAException: Error during remote device query
- Type : syngo.Services.TF.ProcessControl.Activities.Network.Dicom.DicomServiceNetworkException, syngo.Services.TF.ProcessControl.Activities, Version=1.1.0.0, Culture=neutral, PublicKeyToken=008145f79b9aec14
- Message : failure dimse code received for CFIND, dimse status: 0xA900 (CFindFailureInvalidDataset), Failure: Identifier does not match SOP class, Error Comment: Invalid query
- Context Messages:
- Exception in protocol, transporting exception through thread boundaries from queue:_LONGRUNNING_QUEUE_cFindScuQueryActivity1d29a7f6c-947e-4890-9c73-0a53aae0de01
- Current protocol:
- DicomScuQueryProtocol
- Activities in current protocol
- ConvertSyngoUidTypeToSopClassActivity1 : Closed
- readSystemConfigActivity1 : Closed
- ReadDicomNodeConfigActivity1 : Closed
- BuildSOPClassListActivity1 : Closed
- cFindScuPrepareActivity1 : Closed
- CorrectDataSetActivity1 : Closed
- BuildScuPresentationContextListActivity1 : Closed
- ReadTransferPreferencesConfigActivity1 : Closed
- openAssociationActivity1 : Closed
- cFindScuQueryActivity1 : Faulting
- closeAssociationActivity1 : Initialized
- faultHandlersActivity1 : Initialized
- cancellationHandlerActivity1 : Initialized
- Protocol properties:
- ConditionDataSet : DataSet(WritableDataObject(state: NotAdded, delta: 1 element (0x00080061: CSElement(String) VR=CS), readonly part: null))
- ReturnDataSet : DataSet(WritableDataObject(state: NotAdded, delta: 12 elements, readonly part: null))
- QueryDevice : <DeviceHandle DeviceType='DicomNetwork' DeviceLocati>
- QueryDeviceLocation : CGM_PACS
- QueryObjectType : syngo.Services.InformationModel.IStudySyngoUid
- QueryFunctionType : Query
- AutoRetryCount : 0
- RemoteFunctionalDevicePort : 0
- RemoteFunctionalDeviceIsSecure : False
- InjectFaultHandler : False
- InactivityTimeout : 0
- Activities:
- ConvertSyngoUidTypeToSopClassActivity1
- readSystemConfigActivity1
- ReadDicomNodeConfigActivity1
- BuildSOPClassListActivity1
- cFindScuPrepareActivity1
- CorrectDataSetActivity1
- BuildScuPresentationContextListActivity1
- ReadTransferPreferencesConfigActivity1
- openAssociationActivity1
- cFindScuQueryActivity1
- closeAssociationActivity1
- faultHandlersActivity1
- cancellationHandlerActivity1
- EnabledActivities:
- ConvertSyngoUidTypeToSopClassActivity1
- readSystemConfigActivity1
- ReadDicomNodeConfigActivity1
- BuildSOPClassListActivity1
- cFindScuPrepareActivity1
- CorrectDataSetActivity1
- BuildScuPresentationContextListActivity1
- ReadTransferPreferencesConfigActivity1
- openAssociationActivity1
- cFindScuQueryActivity1
- closeAssociationActivity1
- Name : DicomScuQueryProtocol
- Enabled : True
- QualifiedName : DicomScuQueryProtocol
- Description :
- ExecutionStatus : Executing
- ExecutionResult : None
- IsDynamicActivity : False
- UserData:
- 298cf3e0-e9e0-4d41-a11b-506e9132eb27 : False
- b56cb191-96ae-40fd-a640-955a6abd733f : System.Collections.Hashtable
- System.Workflow.ComponentModel.PersistOnCloseAttribute : False
- ===================
- Activity name:
- cFindScuQueryActivity1
- Activity properties:
- DicomDataSet_In : syngo.Services.TF.ProcessControl.Activities.DataSetWrapper
- QueryDevice_In : <DeviceHandle DeviceType='DicomNetwork' DeviceLocati>
- QueryObjectType_In : syngo.Services.InformationModel.IStudySyngoUid
- IgnoreReturnedRetrievedAETFlag_In : False
- RelationalStudyRootQueryFlag_In : False
- RelationalPatientRootQueryFlag_In : True
- AssociationHandler_In : syngo.Services.TF.Basic.Network.Dicom.ScuDicomAssociationHandler
- CurrentTransferPreferences_In:
- MemoryAllocationParameters.HighWaterMark : 209715200
- MemoryAllocationParameters.InitialBuffers : 1
- MemoryAllocationParameters.InitialBufferSize : 524288
- MemoryAllocationParameters.LowWaterMark : 20971520
- MaxNrOfResponses : 100000
- TerminationTimeoutPostCancellation : 4
- TransferFormatStrategy.TransferFormatOptimization : HighNetworkBandwidth
- TransferFormatStrategy.TransferSyntaxExclusionList :
- NetworkTimeOut.TimeUnit : Second
- NetworkTimeOut.AssociationNegotiationTimeOut : 30
- NetworkTimeOut.TransferInactivityTimeOut : 30
- NetworkTimeOut.SocketTimeOut : 5
- SupportedApplicationContextNameList : 1.2.840.10008.3.1.1.1
- TcpIpParameters.PduMaximumLength : 32768
- TcpIpParameters.SendBufferSize : 66560
- TcpIpParameters.ReceiveBufferSize : 66560
- TcpIpParameters.Min : 8192
- TcpIpParameters.CertificateStore : My
- TcpIpParameters.CertificateThumbprint :
- TcpIpParameters.PinnedCertificateThumbprints :
- TcpIpParameters.CertificateRevocationCheck : true
- TcpIpParameters.EnableCertificatePinning : true
- DicomTracing.Domain :
- DicomTracing.Marker :
- DicomTracing.ActivationTimestampUtc :
- RemoteDicomNode_In : NRSTORE
- DefaultScsList_In :
- ISO_IR 100
- LanguageScsDict_In :
- [English (ISO IR6), syngo.Common.Configuration.ConfigList`1[System.String]]
- [English (ISO IR100), syngo.Common.Configuration.ConfigList`1[System.String]]
- [German (ISO IR100), syngo.Common.Configuration.ConfigList`1[System.String]]
- [French (ISO IR100), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Spanish (ISO IR100), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Japanese Katakana/Romaji(ISO IR13/14), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Japanese Kanji(ISO IR87/159), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Unicode (UTF-8), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Chinese (GB18030), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Turkish (ISO IR148), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Cyrillic (ISO IR144), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Arabic (ISO IR127), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Greek (ISO IR126), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Hebrew (ISO IR138), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Thai (ISO IR166), syngo.Common.Configuration.ConfigList`1[System.String]]
- [Korean KS X 1001 (ISO IR149), syngo.Common.Configuration.ConfigList`1[System.String]]
- RemoteSystemDeviceVendorData_In:
- SystemDeviceRole : PACS
- SystemDeviceRoleAppearanceOrder : 20
- IsArchive : false
- IsDefaultArchive : false
- IsPrefetchingSystem : false
- HelpText :
- SupportsExplicitlyRelationalQuery : false
- SupportsImplicitlyRelationalQuery : false
- ProductInfo : syngo.via.VA10A advanced workstation.
- ProductUid :
- ImplementationClassUid :
- ImplementationVersionName :
- SupportAutoNodeConfig : false
- SupportedApplicationContextNameList : 1.2.840.10008.3.1.1.1
- SupportedProtocolVersionList : 1
- AssociationCloseToSeriesCompleteTimeout : 0
- IsRis : false
- IsDefaultRis : false
- TransformationsForQueriesRequests :
- ForceLevelForSCSAttributeInQueryResponse : 0
- EncapsulateNotSupportedObjects : true
- EncapsulationFormat : 1.2.840.10008.5.1.4.1.1.88.11
- AttachedLutType : CorrectionLut
- IgnoreCheckUIDsInATEvents : false
- CloseMoveAssociationOnFinalMoveRSP : false
- Supports12Bit : true
- Illumination : 2000
- ReflectedAmbientLight : 10
- StorageFallbackStrategy : ManualRepeat
- StorageFallbackRedirectionNode :
- ForceStudyLevelQueryRetrieve : false
- IgnoreReturnedRetrievedAET : false
- IgnoreMoveOriginatorFromStoreRequests : false
- IgnoreLastATEvents : false
- MaxNumberOfParallelQueryAssociations : 0
- IgnoreWaitAfterLastATEvent : false
- MppsSourceNodeList :
- NoSetInProgressFlag : false
- NoAppendCaseFlag : false
- TransformationsForMppsMessages :
- DicomServerOutFolder : %TEMP%DicomServerout
- ForceSCSAttributeInWorklistQueryRequest : false
- ExcludedSOPClasses :
- CFindDimseInvoker_Out : syngo.Services.TF.Basic.Network.Dicom.Dimse.CFindDimseInvoker
- MessageId_Out : 1
- AcceptedTransferSyntax_Out : ExplicitValueRepresentationLittleEndian
- TimeOut_In : 65000
- Parent : DicomScuQueryProtocol [syngo.Services.TF.ProcessControl.Activities.Network.Dicom.DicomScuQueryProtocol]
- Name : cFindScuQueryActivity1
- Enabled : True
- QualifiedName : cFindScuQueryActivity1
- Description :
- ExecutionStatus : Faulting
- ExecutionResult : None
- IsDynamicActivity : False
- UserData:
- 298cf3e0-e9e0-4d41-a11b-506e9132eb27 : False
- System.Workflow.ComponentModel.AlternateFlowActivityAttribute : False
- System.Workflow.ComponentModel.PersistOnCloseAttribute : False
- syngo.Services.TF.Common.Messages.DicomFindScuDimseError: The remote node with AET NRSTORE has interrupted the Dicom Query with DIMSE status "Failure: Identifier does not match SOP class" (Code: 0xA900).
- Data[Offending Elements]:
- Data[OriginalExceptionStackInThread50096]: at syngo.Services.TF.ProcessControl.Activities.Network.Dicom.CFindScuQueryActivity.HandleNewMessage(Object eventRaiser, IDimseResponseEventArgs dimseResponseArgs)
- Data[RethrownExceptionStackInThread108]: at syngo.Services.TF.ProcessControl.Activities.Network.Dicom.CFindScuQueryActivity.SendQueryRequest()
- at syngo.Services.TF.ProcessControl.Activities.Network.Dicom.CFindScuQueryActivity.OnWorkingBoxHandler(Object data)
- at syngo.Services.TF.ProcessControl.ProtocolEngine.ProtocolEngineService.ActivityWBExecutor.InvokeWorkingBoxDelegate(Object p)
- at syngo.Services.TF.ProcessControl.ProtocolEngine.ProtocolEngineService.WorkingBoxHandler(WBMessage wb)
- at syngo.Common.Core.Internal.ObjectTask.RunWbLoop()
- Source : syngo.Services.TF.ProcessControl.Activities
- TargetSite : Void HandleNewMessage(System.Object, syngo.Services.TF.Basic.Network.Dicom.Dimse.IDimseResponseEventArgs)
- Stack Trace : at System.Workflow.ComponentModel.ThrowActivity.Execute(ActivityExecutionContext executionContext)
- at System.Workflow.ComponentModel.ActivityExecutorOperation.Run(IWorkflowCoreRuntime workflowCoreRuntime)
- at System.Workflow.Runtime.Scheduler.Run()
- Outer Exception
- ---------------
- Type : syngo.Services.QueryExecutionException, syngo.Services, Version=1.1.0.0, Culture=neutral, PublicKeyToken=008145f79b9aec14
- Message : Protocol aborted
- Source : syngo.Services.TF.Component.Network.Core
- TargetSite : Void OnProtocolAborted(System.Object, syngo.Services.TF.ProcessControl.ProtocolEngine.ProtocolInstanceEventArgs)
- Stack Trace : at syngo.Services.TF.Component.Network.Core.Providers.Dicom.DicomQuery.OnProtocolAborted(Object sender, ProtocolInstanceEventArgs protocolArgs)
- Outer Exception
- ---------------
- Type : syngo.Services.sDM.NavigatorService.NavigatorCDMAException, syngo.Services.sDM.NavigatorService, Version=1.0.0.0, Culture=neutral, PublicKeyToken=008145f79b9aec14
- Message : Error during remote device query
- Context Messages:
- syngo.Services.sDM.NavigatorService.Resources.EMHResources.MEDIA_CDMA_SYSLOG: CDMA exception occured while remote search.
- Source :
- FailedDevice : CGM_PACS
- TargetSite :
- Stack Trace : The stack trace is unavailable.
- Additional Info:
- MachineName : SYNGOVIA
- TimeStamp : 2023-06-08T15:47:12.195-07:00
- AppDomainName: syngo.Services.sDM.Server.exe
- ThreadIdentity: *****
- WindowsIdentity: *****
- ID: syngo_Exception.syngo.Services.sDM.NavigatorService.NavigatorCDMAException
- Severity: Error
- Timestamp: 2023-06-08T15:47:12.195-07:00
- Process Name: C:Program FilesSiemenssyngobinsyngo.Services.sDM.Server.exe
- Process Id: 48444
- Thread Name: syngo WB 86 AOM standard processor [SRV]
- Thread Id: 52196
- AppDomain: syngo.Services.sDM.Server.exe
- Machine: SYNGOVIA
- EventSource: Exception
- Process Start Time: 2023-06-08T05:00:23.778-07:00
- Extended Properties: MsgCreateTime - 2023-06-08T15:47:12.195-07:00
- BuildNumber - VIA.PCP.VB60A.HF03.NB_20220519.1
- syngoSource - syngo.Services.TF.Component.Network.Core.Providers.Dicom.DicomQuery
- ExceptionId - 0_341289192E2E8C04266E9DA14BB109EEE87311F641396D0AF904B554A62B16
- ExceptionInstanceId - 409939e7-7b60-4cfa-8d9d-6e84ddaab0b1
- OriginalSeverity - Error